A Cadaveric Study of Thread Cubital Tunnel Release with Newly Developed Threads

Minsuk Kang, Yong Seok Nam, In Jong Kim, Hae Yeon Park, Jung Ryul Ham, Jae Min Kim

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

Objective: The percutaneous thread transection technique is a surgical dissecting method using a dissecting thread inserted through a needle under ultrasound guidance without skin incision. As the new dissecting threads were developed domestically, this cadaver study was conducted to compare the effectiveness and safety between the new threads (ultra V sswire and smartwire-01) and a pre-existing commercial dissecting thread (loop & shear) by demonstrating a modified looped thread cubital tunnel release. Methods: The percutaneous cubital tunnel release procedure was performed on 29 fresh cadaveric upper extremities. The pre-existing commercial thread was used in 5 upper extremities. The two newly developed threads were used in 24 upper extremities. Two practitioners performed the procedures separately. After the modified looped thread cubital release, anatomical and histological analyses were performed by a blinded anatomist. The presence of the dissected cubital tunnel and damaged adjacent soft tissue was assessed. Results: Out of the 29 cadaveric upper extremities, 27 specimens showed complete dissection of the Osborne ligament and the proximal fascia of the flexor carpi ulnaris muscle. One specimen was incompletely dissected in each of the ultra V sswire and smartwire-01 groups. There were no injuries of adjacent structures including the ulnar nerve, ulnar artery, medial antebrachial cutaneous nerve, or flexor tendon with either the commercial thread or the newly developed threads. The anatomical analysis revealed clear and sharp incisional margins of the cubital tunnel in the Smartwire-01 and loop & shear groups. All three kinds of threads maintained proper linear elasticity for easy handling during the procedure. The smartwire-01 provided higher visibility in ultrasound than the other threads. Conclusion: The newly developed threads were effective and safe for use in the thread cubital tunnel release procedure.

Original languageEnglish
Pages (from-to)307-314
Number of pages8
JournalJournal of Korean Neurosurgical Society
Volume65
Issue number2
DOIs
StatePublished - Mar 2022

Keywords

  • Anatomy and histology
  • Cadaver
  • Cubital tunnel syndrome
  • Ultrasonography

Fingerprint

Dive into the research topics of 'A Cadaveric Study of Thread Cubital Tunnel Release with Newly Developed Threads'. Together they form a unique fingerprint.

Cite this