Abstract

The purpose of this study was to measure and correlate the fitness and trueness of a 3-unit fixed dental prosthesis (FDP) fabricated using two digital workflows. The 3-unit FDPs were fabricated using two digital workflows (N = 15). The digital workflows were divided into chairside (closed type) and in-lab (open type) groups. The scanning, computer-aided design (CAD), and computer-aided manufacturing (CAM) processes were conducted with 3shape E1 scanner, exocad CAD software, and DDS EZIS HM, respectively, in the in-lab group; and with CEREC omnicam intraoral scanner, CEREC CAD software, and CEREC MC XL, respectively, in the chairside group. The fitness of the fabricated 3-unit FDPs was evaluated by scanning the silicone replica of the cement space and analyzing the thickness of the silicone replica in the three-dimensional (3D) inspection software (Geomagic control X). The trueness of the milling unit was analyzed by 3D analysis of the CAD reference model, which is the design file of the 3-unit FDP, and the CAD test model, which is the scanned file of the 3-unit FDP. In the statistical analysis, comparison of the two groups was conducted by Mann-Whitney U test, and the correlation between the fitness and trueness was conducted by Pearson correlation test (α = 0.05). The marginal and internal fit were significantly lower in the in-lab group at all measurement positions (p < 0.001). The trueness of the milling unit was significantly higher in the in-lab group compared to the chairside group (p < 0.001). There was a positive correlation between the trueness and internal fit (correlation coefficient = 0.621) in the in-lab group (p = 0.013). The use of appropriate equipment in an in-lab (open type) digital workflow enables a better fabrication of 3-unit FDPs than a chairside (closed type) digital workflow, and poor trueness on the inner surface of the crown adversely affects the internal fit.

Original languageEnglish
Article number2778
JournalApplied Sciences (Switzerland)
Volume9
Issue number14
DOIs
StatePublished - 1 Jul 2019

Keywords

  • Dental CAD-CAM
  • Dental ceramic
  • Dentistry
  • Marginal and internal fit
  • Trueness

Fingerprint

Dive into the research topics of 'A comparative study of the fitness and trueness of a three-unit fixed dental prosthesis fabricated using two digital workflows'. Together they form a unique fingerprint.

Cite this