TY - JOUR
T1 - A dual-frequency colinear array for acoustic angiography in prostate cancer evaluation
AU - Li, Sibo
AU - Kim, Jinwook
AU - Wang, Zhuochen
AU - Kasoji, Sandeep
AU - Lindsey, Brooks D.
AU - Dayton, Paul A.
AU - Jiang, Xiaoning
N1 - Publisher Copyright:
© 2018 IEEE.
PY - 2018/12
Y1 - 2018/12
N2 - Approximately 80% of men who reach 80 years of age will have some form of prostate cancer. The challenge remains to differentiate benign and malignant lesions. Based on recent research, acoustic angiography, a novel contrast-enhanced ultrasound imaging technique, can provide high-resolution visualization of tissue microvasculature and has demonstrated the ability to differentiate vascular characteristics between healthy and tumor tissue in preclinical studies. We hypothesize that transrectal acoustic angiography may enhance the assessment of prostate cancer. In this paper, we describe the development of a dual frequency, dual-layer colinear array transducer for transrectal acoustic angiography. The probe consists of 64 transmitting (TX) elements with a center frequency of 3 MHz and 128 receiving (RX) elements with a center frequency of 15 MHz. The dimensions of the array are 18 mm in azimuth and 9 mm in elevation. The pitch is 280 µm for TX elements and 140 µm for RX elements. Pulse-echo tests of TX/RX elements and aperture acoustic field measurements were conducted, and both results were compared with the simulation results. Real-time contrast imaging was performed using a Verasonics system and a tissue-mimicking phantom. Nonlinear acoustic responses from microbubble contrast agents at a depth of 35 mm were clearly observed. In vivo imaging in a rodent model demonstrated the ability to detect individual vessels underneath the skin. These results indicate the potential use of the array described herein for acoustic angiography imaging of prostate tumor and identification of regions of neovascularization for the guidance of prostate biopsies.
AB - Approximately 80% of men who reach 80 years of age will have some form of prostate cancer. The challenge remains to differentiate benign and malignant lesions. Based on recent research, acoustic angiography, a novel contrast-enhanced ultrasound imaging technique, can provide high-resolution visualization of tissue microvasculature and has demonstrated the ability to differentiate vascular characteristics between healthy and tumor tissue in preclinical studies. We hypothesize that transrectal acoustic angiography may enhance the assessment of prostate cancer. In this paper, we describe the development of a dual frequency, dual-layer colinear array transducer for transrectal acoustic angiography. The probe consists of 64 transmitting (TX) elements with a center frequency of 3 MHz and 128 receiving (RX) elements with a center frequency of 15 MHz. The dimensions of the array are 18 mm in azimuth and 9 mm in elevation. The pitch is 280 µm for TX elements and 140 µm for RX elements. Pulse-echo tests of TX/RX elements and aperture acoustic field measurements were conducted, and both results were compared with the simulation results. Real-time contrast imaging was performed using a Verasonics system and a tissue-mimicking phantom. Nonlinear acoustic responses from microbubble contrast agents at a depth of 35 mm were clearly observed. In vivo imaging in a rodent model demonstrated the ability to detect individual vessels underneath the skin. These results indicate the potential use of the array described herein for acoustic angiography imaging of prostate tumor and identification of regions of neovascularization for the guidance of prostate biopsies.
UR - http://www.scopus.com/inward/record.url?scp=85054366739&partnerID=8YFLogxK
U2 - 10.1109/TUFFC.2018.2872911
DO - 10.1109/TUFFC.2018.2872911
M3 - Article
C2 - 30281447
AN - SCOPUS:85054366739
SN - 0885-3010
VL - 65
SP - 2418
EP - 2428
JO - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
JF - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
IS - 12
ER -