TY - JOUR
T1 - A novel vertebroplasty technique using a larger-diameter needle for thoracolumbar osteoporotic vertebral compression fracture
AU - Park, Eugene J.
AU - Lee, Ho Jin
AU - Jang, Min Gu
AU - Ahn, Jae Sung
AU - Kim, Sang Bum
N1 - Publisher Copyright:
© 2021 the Author(s). Published by Wolters Kluwer Health, Inc.
PY - 2021/6/4
Y1 - 2021/6/4
N2 - Percutaneous vertebroplasty (VP) and kyphoplasty (KP) are well-established minimally invasive surgical procedures for the treatment of osteoporotic vertebral compression fractures (OVCF). However, some drawbacks have been reported regarding these procedures, including height loss, cement leakage, and loss of the restored height after balloon deflation. We performed a novel VP technique to minimize these limitations of conventional procedures. This study aimed to compare radiological and clinical outcomes of our method using a larger-diameter needle versus conventional VP (using a smaller needle) for thoracolumbar OVCF.From April 2016 to May 2017, 107 consecutive patients diagnosed with thoracolumbar OVCF were enrolled. Patients were divided into two groups: group 1 underwent conventional VP, i.e., using a smaller diameter needle, and group 2 underwent VP through a modified method with a larger-diameter needle. For radiological evaluation, parameters related to anterior vertebral height (AVH) and segmental angle were assessed using plain standing radiographs, and patient-reported outcomes were evaluated using the visual analog scale. Cement injection amount and leakage pattern were also analyzed. Group 2 showed a larger anterior vertebral height change than group 1 immediately postoperatively and one year postoperatively. The 1-year postoperatively-AVH maintained better in group 2 than in group 1. Group 2 showed more significant improvement of segmental angle immediately postoperatively than group 1 (3.15° in group 1 vs 9.36° in group 2). IYPo-visual analog scale significantly improved in both groups, with greater improvement in group 2 (3.69 in group 1 vs 5.63 in group 2). A substantially larger amount of cement was injected, with a lower leakage rate in group 2 than in group 1.A novel VP technique using a larger-diameter needle showed superior radiological and clinical outcomes than conventional VP. Therefore, it can be considered a useful treatment option for OVCF.
AB - Percutaneous vertebroplasty (VP) and kyphoplasty (KP) are well-established minimally invasive surgical procedures for the treatment of osteoporotic vertebral compression fractures (OVCF). However, some drawbacks have been reported regarding these procedures, including height loss, cement leakage, and loss of the restored height after balloon deflation. We performed a novel VP technique to minimize these limitations of conventional procedures. This study aimed to compare radiological and clinical outcomes of our method using a larger-diameter needle versus conventional VP (using a smaller needle) for thoracolumbar OVCF.From April 2016 to May 2017, 107 consecutive patients diagnosed with thoracolumbar OVCF were enrolled. Patients were divided into two groups: group 1 underwent conventional VP, i.e., using a smaller diameter needle, and group 2 underwent VP through a modified method with a larger-diameter needle. For radiological evaluation, parameters related to anterior vertebral height (AVH) and segmental angle were assessed using plain standing radiographs, and patient-reported outcomes were evaluated using the visual analog scale. Cement injection amount and leakage pattern were also analyzed. Group 2 showed a larger anterior vertebral height change than group 1 immediately postoperatively and one year postoperatively. The 1-year postoperatively-AVH maintained better in group 2 than in group 1. Group 2 showed more significant improvement of segmental angle immediately postoperatively than group 1 (3.15° in group 1 vs 9.36° in group 2). IYPo-visual analog scale significantly improved in both groups, with greater improvement in group 2 (3.69 in group 1 vs 5.63 in group 2). A substantially larger amount of cement was injected, with a lower leakage rate in group 2 than in group 1.A novel VP technique using a larger-diameter needle showed superior radiological and clinical outcomes than conventional VP. Therefore, it can be considered a useful treatment option for OVCF.
KW - osteoporotic fracture
KW - patient reported outcome measures
KW - radiography
KW - vertebroplasty
UR - http://www.scopus.com/inward/record.url?scp=85107782519&partnerID=8YFLogxK
U2 - 10.1097/MD.0000000000026174
DO - 10.1097/MD.0000000000026174
M3 - Article
C2 - 34087881
AN - SCOPUS:85107782519
SN - 0025-7974
VL - 100
SP - E26174
JO - Medicine (United States)
JF - Medicine (United States)
IS - 22
ER -