TY - JOUR
T1 - Analysis of bacterial inactivation by intense pulsed light using a double-Weibull survival model
AU - Hwang, Hee Jeong
AU - Seo, Ji Hyun
AU - Jeong, Chanmin
AU - Cheigh, Chan Ick
AU - Chung, Myong Soo
N1 - Publisher Copyright:
© 2019 Elsevier Ltd
PY - 2019/8
Y1 - 2019/8
N2 - The objective of this study was to measure the inactivation efficiencies of intense pulsed light (IPL) on six types of bacteria and determine how the efficiency values are related to the spectral transmittance of IPL. All of the microorganisms exhibited up to 7-log CFU/mL reductions, and the double-Weibull survival model provided the best fit to the inactivation curves. We obtained 4Dv values (which is the fluence required to inactivate 99.99% of viable cells) and zv values (which is the increase in lamp voltage required for a 1-log reduction of the 4Dv value) for lamp voltages ranging from 800 to 1800 V (corresponding to total fluences from 0.00 to 11.41 J/cm2). The 4Dv values for Bacillus cereus, Clostridium perfringens, Staphylococcus aureus, Pseudomonas aeruginosa, Salmonella Enteritidis, and Shigella sonnei for IPL treatment at 1800 V were 1.57, 0.66, 0.62, 0.79, 0.66, and 1.63 J/cm2, respectively, while the corresponding zv values were 5553, 3590, 3201, 3678, 3672, and 6440 V, respectively. The variations in the sensitivity to IPL were related to differences in the transmittance of the microorganisms. A practical model was developed to predict the 4Dv values of microorganisms based on their transmittance and the IPL lamp voltage.
AB - The objective of this study was to measure the inactivation efficiencies of intense pulsed light (IPL) on six types of bacteria and determine how the efficiency values are related to the spectral transmittance of IPL. All of the microorganisms exhibited up to 7-log CFU/mL reductions, and the double-Weibull survival model provided the best fit to the inactivation curves. We obtained 4Dv values (which is the fluence required to inactivate 99.99% of viable cells) and zv values (which is the increase in lamp voltage required for a 1-log reduction of the 4Dv value) for lamp voltages ranging from 800 to 1800 V (corresponding to total fluences from 0.00 to 11.41 J/cm2). The 4Dv values for Bacillus cereus, Clostridium perfringens, Staphylococcus aureus, Pseudomonas aeruginosa, Salmonella Enteritidis, and Shigella sonnei for IPL treatment at 1800 V were 1.57, 0.66, 0.62, 0.79, 0.66, and 1.63 J/cm2, respectively, while the corresponding zv values were 5553, 3590, 3201, 3678, 3672, and 6440 V, respectively. The variations in the sensitivity to IPL were related to differences in the transmittance of the microorganisms. A practical model was developed to predict the 4Dv values of microorganisms based on their transmittance and the IPL lamp voltage.
KW - D value
KW - Foodborne pathogens
KW - Intense pulsed light (IPL)
KW - Sensitivity
KW - Transmittance
KW - z value
UR - http://www.scopus.com/inward/record.url?scp=85068145309&partnerID=8YFLogxK
U2 - 10.1016/j.ifset.2019.102185
DO - 10.1016/j.ifset.2019.102185
M3 - Article
AN - SCOPUS:85068145309
SN - 1466-8564
VL - 56
JO - Innovative Food Science and Emerging Technologies
JF - Innovative Food Science and Emerging Technologies
M1 - 102185
ER -