T1 - Analysis of the contactless power transfer system using modelling and analysis of the contactless transformer
AU - Ryu, Myunghyo
AU - Cha, Honnyong
AU - Park, Yonghwan
AU - Baek, Juwon
PY - 2005
Y1 - 2005
N2 - In this paper, the electrical characteristics of the contactless transformer is presented using conventional coupled inductor theory. Compared with the conventional transformer, a contactless transformer has large airgap, long primary wire and multi-secondary wire. So contactless transformer has large leakage inductance, small magnetizing inductance and poor coupling coefficient. Therefore, large magnetizing current flows through entire primary system due to small magnetizing inductance and the overall system effieciency will be low. In high power applications, contactless transformer is so bulky and heavy that it should be split by some light and small transformers. So contactless transformer needs several small transformer modules which are connected series or parallel to transfer the primary power to the secondary one. This paper shows analsis and measurement results of the each contactless transformer module and comparison results between series-connection and parallel-connection of the contactless transformer. The results are verified on the simulation based on the theoretical analysis and the 30kW experimental prototype.
AB - In this paper, the electrical characteristics of the contactless transformer is presented using conventional coupled inductor theory. Compared with the conventional transformer, a contactless transformer has large airgap, long primary wire and multi-secondary wire. So contactless transformer has large leakage inductance, small magnetizing inductance and poor coupling coefficient. Therefore, large magnetizing current flows through entire primary system due to small magnetizing inductance and the overall system effieciency will be low. In high power applications, contactless transformer is so bulky and heavy that it should be split by some light and small transformers. So contactless transformer needs several small transformer modules which are connected series or parallel to transfer the primary power to the secondary one. This paper shows analsis and measurement results of the each contactless transformer module and comparison results between series-connection and parallel-connection of the contactless transformer. The results are verified on the simulation based on the theoretical analysis and the 30kW experimental prototype.
KW - Contactless Power Transfer System
KW - Contactless Transformer
KW - Coupled Inductor Theory
UR - http://www.scopus.com/inward/record.url?scp=33749669248&partnerID=8YFLogxK
U2 - 10.1109/IECON.2005.1569047
DO - 10.1109/IECON.2005.1569047
M3 - Conference contribution
AN - SCOPUS:33749669248
SN - 0780392523
SN - 9780780392526
T3 - IECON Proceedings (Industrial Electronics Conference)
SP - 1036
EP - 1042
BT - IECON 2005
T2 - IECON 2005: 31st Annual Conference of IEEE Industrial Electronics Society
Y2 - 6 November 2005 through 10 November 2005
ER -