Analysis on discharge modes in AC-PDP with sustain gap of 200 μm

Jae Young Kim, Soo Kwan Jang, Ki Hyung Park, Choon Sang Park, Heung Sik Tae

Research output: Contribution to conferencePaperpeer-review

Abstract

The Vt close curve measurement shows that there exists the X-Y discharge contour in the large sustain gap of 200 μm (> a barrier rib height of 125 μm). This indicates that there are two different discharge modes: one mode is that the discharge is produced only between the sustain electrodes, and the other mode is that the discharge is initiated between the address and sustain electrodes, thus producing the main discharge between the sustain electrodes. The two discharge modes are confirmed and analyzed based on Vt close curve movement on cell voltage plane after the strong discharge. The two discharge modes show the different discharge characteristics such as a sustainable region, Vt close curve behavior, and luminance. Furthermore, it is observed that the discharge characteristics induced by applying the short address pulse are different according the discharge mode.

Original languageEnglish
Pages268-271
Number of pages4
StatePublished - 2005
EventSecond Americas Display Engineering and Applications Conference, ADEAC 2005 - Portland, OR, United States
Duration: 25 Oct 200527 Oct 2005

Conference

ConferenceSecond Americas Display Engineering and Applications Conference, ADEAC 2005
Country/TerritoryUnited States
CityPortland, OR
Period25/10/0527/10/05

Fingerprint

Dive into the research topics of 'Analysis on discharge modes in AC-PDP with sustain gap of 200 μm'. Together they form a unique fingerprint.

Cite this