Angular deformity correction by guided growth in growing children: Eight-plate versus 3.5-mm reconstruction plate

Kyeong Hyeon Park, Chang Wug Oh, Joon Woo Kim, Il Hyung Park, Hee June Kim, Young Seo Choi

Research output: Contribution to journalArticlepeer-review

8 Scopus citations

Abstract

Background Guided growth using the eight-plate (8-plate) is the most commonly used method to correct angular deformities in children; however, implant failure has been reported. Recently, the 3.5-mm reconstruction plate (R-plate) has been used as an alternative option for guided growth; however, hardware prominence has been problematic. This study aimed to compare the coronal angular deformity correction results of guided growth between relatively thin 8-plates with cannulated screws and thick R-plates with solid screws. Methods Thirty-nine physes (24 distal femoral, 15 proximal tibial) in 20 patients underwent hemiepiphysiodesis using 8-plates, and 61 physes (40 distal femoral, 21 proximal tibial) in 35 patients underwent hemiepiphysiodesis using R-plates. Coronal angular corrections were measured and compared preoperatively, and after the completion of corrections. Amounts and rates of correction and complications were compared between the groups. Results Mean body mass index was 18.7 kg/m2 in the 8-plate group, and 22.7 kg/m2 in the R-plate group. Angular correction was achieved in all deformities at a mean of 13.7 months and 19.7 months in the 8-plate and the R-plate group, respectively. The mean corrected mechanical lateral distal femoral angle was 9.0° in the 8-plate group, and 9.9° in the R-plate group (P = 0.55). The mean corrected medial proximal tibial angle was 7.1° in the 8-plate group, and 9.0° in the R-plate group (P = 0.07). The mean rates of angular correction were also not significantly different in the distal femur (1.03°/month vs. 0.77°/month, P = 0.2) and the proximal tibia (0.66°/month vs. 0.63°/month, P = 0.77). There was one superficial infection in each group, and one case of implant failure in the R-plate group. Two rebound deformities were observed and needed repeat hemiepiphysiodesis. Permanent physeal arrest was not observed in this series.

Original languageEnglish
Pages (from-to)919-923
Number of pages5
JournalJournal of Orthopaedic Science
Volume22
Issue number5
DOIs
StatePublished - Sep 2017

Fingerprint

Dive into the research topics of 'Angular deformity correction by guided growth in growing children: Eight-plate versus 3.5-mm reconstruction plate'. Together they form a unique fingerprint.

Cite this