Automatic registration between real-time ultrasonography and pre-procedural magnetic resonance images: A prospective comparison between two registration methods by liver surface and vessel and by liver surface only

Ah Yeong Kim, Min Woo Lee, Dong Ik Cha, Hyo Keun Lim, Young Taek Oh, Ja Yeon Jeong, Jung Woo Chang, Jiwon Ryu, Kyong Joon Lee, Jaeil Kim, Won Chul Bang, Dong Kuk Shin, Sung Jin Choi, Dalkwon Koh, Bong Koo Seo, Kyunga Kim

Research output: Contribution to journalArticlepeer-review

12 Scopus citations

Abstract

The aim of this study was to compare the accuracy of and the time required for image fusion between real-time ultrasonography (US) and pre-procedural magnetic resonance (MR) images using automatic registration by a liver surface only method and automatic registration by a liver surface and vessel method. This study consisted of 20 patients referred for planning US to assess the feasibility of percutaneous radiofrequency ablation or biopsy for focal hepatic lesions. The first 10 consecutive patients were evaluated by an experienced radiologist using the automatic registration by liver surface and vessel method, whereas the remaining 10 patients were evaluated using the automatic registration by liver surface only method. For all 20 patients, image fusion was automatically executed after following the protocols and fused real-time US and MR images moved synchronously. The accuracy of each method was evaluated by measuring the registration error, and the time required for image fusion was assessed by evaluating the recorded data using in-house software. The results obtained using the two automatic registration methods were compared using the Mann-Whitney U-test. Image fusion was successful in all 20 patients, and the time required for image fusion was significantly shorter with the automatic registration by liver surface only method than with the automatic registration by liver surface and vessel method (median: 43.0 s, range: 29-74 s vs. median: 83.0 s, range: 46-101 s; p = 0.002). The registration error did not significantly differ between the two methods (median: 4.0 mm, range: 2.1-9.9 mm vs. median: 3.7 mm, range: 1.8-5.2 mm; p = 0.496). The automatic registration by liver surface only method offers faster image fusion between real-time US and pre-procedural MR images than does the automatic registration by liver surface and vessel method. However, the degree of accuracy was similar for the two methods.

Original languageEnglish
Pages (from-to)1627-1636
Number of pages10
JournalUltrasound in Medicine and Biology
Volume42
Issue number7
DOIs
StatePublished - 1 Jul 2016

Keywords

  • Biopsy
  • Fusion imaging
  • Magnetic resonance imaging
  • Radiofrequency ablation
  • Registration error
  • Registration time
  • Ultrasound

Fingerprint

Dive into the research topics of 'Automatic registration between real-time ultrasonography and pre-procedural magnetic resonance images: A prospective comparison between two registration methods by liver surface and vessel and by liver surface only'. Together they form a unique fingerprint.

Cite this