Calibration of an ultraviolet distribution model by precise measurement of underwater ultraviolet intensities

Wonhee Lee, Younggyun Choi, Sunghong Kim

Research output: Contribution to journalArticlepeer-review

Abstract

In Korea, disinfection of effluent from a wastewater treatment plant is now essential, and ultraviolet (UV) disinfection is known as one of the useful disinfection alternatives. The non-contact type UV disinfection method, which is distinguished by a fouling-free process, was developed, and a mathematical model for the photoreactor was developed. For the purpose of the model calibration, the study had manufactured a non-contact type UV photoreactor and measured UV intensities within the photoreactor. The two major parameters of the model were evaluated by comparing the UV intensity of the photoreactor and the model’s simulation results. As the result of this study, the developed model for a non-contact type UV photoreactor could predict UV intensity within the photoreactor well. Optima parameter values came out as measuring 576 points for the calibration test and 504 points for the verification test. The coincidence index proved useful in calibrating the parameters, with the index values over 0.9 at the optimum values. This study produced optimum values for the two parameters. The UV conversion efficiency and the transmittance of UV in pure water came out to be 0.56 and 100%, respectively.

Original languageEnglish
Pages (from-to)1780-1785
Number of pages6
JournalKorean Journal of Chemical Engineering
Volume31
Issue number10
DOIs
StatePublished - 7 Oct 2014

Keywords

  • Calibration and Verification
  • Non-contact Type UV Photoreactor
  • UV Disinfection
  • UV Distribution Model
  • UV Transmittance

Fingerprint

Dive into the research topics of 'Calibration of an ultraviolet distribution model by precise measurement of underwater ultraviolet intensities'. Together they form a unique fingerprint.

Cite this