Clenching Reduction Technique for Osteosynthesis of Atypical C2 Fractures with the Combining Use of Laminar and Pedicle Screw: A Technical Note

Suk Joong Lee, Woo Kie Min, Hyun Joo Lee, Jong Uk Mun, Ji Yeon Choi

Research output: Contribution to journalArticlepeer-review

Abstract

Atypical C2 fractures refer to all fracture types of the C2 body excluding odontoid fractures and traumatic spondylolisthesis of C2. A 55-year-old male patient presented with neck pain after a vehicular accident. Computed tomography (CT) showed an oblique fracture line of the C2 vertebral body through the pedicle and lamina with fracture gap and posterior displacement. We used a clenching reduction technique to treat this fracture by using an ipsilateral laminar screw and contralateral pedicle screw. The final follow-up CT scan showed complete bone union. Neck motion was preserved including rotation. For this unstable atypical C2 fracture, the clenching reduction technique proved to be a safe and effective technique while salvaging neck motion.

Original languageEnglish
Pages (from-to)169-172
Number of pages4
JournalJournal of Neurological Surgery, Part A: Central European Neurosurgery
Volume79
Issue number2
DOIs
StatePublished - 1 Mar 2018

Keywords

  • atypical C2 fracture
  • clenching reduction technique
  • osteosynthesis

Fingerprint

Dive into the research topics of 'Clenching Reduction Technique for Osteosynthesis of Atypical C2 Fractures with the Combining Use of Laminar and Pedicle Screw: A Technical Note'. Together they form a unique fingerprint.