Comparative study of the trueness of the inner surface of crowns fabricated from three types of lithium disilicate blocks

Keunbada Son, Beom Young Yu, Tae Ho Yoon, Kyu Bok Lee

Research output: Contribution to journalArticlepeer-review

8 Scopus citations

Abstract

This study set out to compare the three-dimensional (3D) trueness of crowns produced from three types of lithium disilicate blocks. The working model was digitized, and single crowns (maxillary left second molar) were designed using computer-aided design (CAD) software. To produce a crown design model (CDM), a crown design file was extracted from the CAD software. In addition, using the CDM file and a milling machine (N = 20), three types of lithium disilicate blocks (e.max CAD, HASS Rosetta, and VITA Suprinity) were processed. To produce a crown scan model (CSM), the inner surface of each fabricated crown was digitized using a touch-probe scanner. In addition, using 3D inspection software, the CDM was partitioned (into marginal, axis, angular, and occlusal regions), the CDM and CSM were overlapped, and a 3D analysis was conducted. A Kruskal-Wallis test (α = 0.05) was conducted with all-segmented teeth with the root mean square (RMS), and they were analyzed using the Mann-Whitney U-test and the Bonferroni correction method as a post hoc test. There was a significant difference in the trueness of the crowns according to the type of lithium disilicate block (p < 0.001). The overall RMS value was at a maximum for e.max (42.9 ± 4.4 μm), followed by HASS (30.1 ± 9.0 μm) and then VITA (27.3 ± 7.9 μm). However, there was no significant difference between HASS and VITA (p = 0.541). There were significant differences in all regions inside the crown (p < 0.001). There was a significantly high trueness in the angular region inside the crown (p < 0.001). A correction could thus be applied in the CAD process, considering the differences in the trueness by the type of lithium disilicate block. In addition, to attain a crown with an excellent fit, it is necessary to provide a larger setting space for the angular region during the CAD process.

Original languageEnglish
Article number1798
JournalApplied Sciences (Switzerland)
Volume9
Issue number9
DOIs
StatePublished - 1 May 2019

Keywords

  • Dental CAD-CAM
  • Dental ceramic
  • Dentistry
  • Three-dimensional analysis
  • Trueness

Fingerprint

Dive into the research topics of 'Comparative study of the trueness of the inner surface of crowns fabricated from three types of lithium disilicate blocks'. Together they form a unique fingerprint.

Cite this