TY - JOUR
T1 - Comprehensive Lists of Internal Calibrants for Ultrahigh-Resolution Mass Spectrometry Analysis of Crude Oil and Natural Organic Matter and Their Preparation Recipes
AU - Cho, Eunji
AU - Solihat, Nissa Nurfajrin
AU - Kim, Young Hwan
AU - Kim, Sunghwan
N1 - Publisher Copyright:
© 2021 American Society for Mass Spectrometry. Published by American Chemical Society. All rights reserved.
PY - 2021/2/3
Y1 - 2021/2/3
N2 - In this work, comprehensive lists of internal calibrants for accurate mass determination of molecules in crude oils, natural organic matter, and soil as well as their preparation recipes are presented. The lists include various sets of chemicals for positive- and negative-ion mode electrospray ionization, atmospheric pressure chemical ionization, atmospheric pressure photoionization, and laser desorption ionization. The chemicals were chosen based on their solvent compatibility, ionization efficiency, and accessibility. The sample preparation process was optimized for each ionization method and type of sample. The lists include detailed information on preparation solvent, concentrations, and mixing ratios of sample and calibrants. Internal calibration using the information in the lists results in successful calibration, and all the data presented in this study show root-mean-square errors between the theoretical and obtained m/z numbers of less than 0.4 ppm. The information presented in this study provides an important guideline for researchers working on complex mixtures with ultrahigh-resolution mass spectrometry.
AB - In this work, comprehensive lists of internal calibrants for accurate mass determination of molecules in crude oils, natural organic matter, and soil as well as their preparation recipes are presented. The lists include various sets of chemicals for positive- and negative-ion mode electrospray ionization, atmospheric pressure chemical ionization, atmospheric pressure photoionization, and laser desorption ionization. The chemicals were chosen based on their solvent compatibility, ionization efficiency, and accessibility. The sample preparation process was optimized for each ionization method and type of sample. The lists include detailed information on preparation solvent, concentrations, and mixing ratios of sample and calibrants. Internal calibration using the information in the lists results in successful calibration, and all the data presented in this study show root-mean-square errors between the theoretical and obtained m/z numbers of less than 0.4 ppm. The information presented in this study provides an important guideline for researchers working on complex mixtures with ultrahigh-resolution mass spectrometry.
UR - http://www.scopus.com/inward/record.url?scp=85099939071&partnerID=8YFLogxK
U2 - 10.1021/jasms.0c00456
DO - 10.1021/jasms.0c00456
M3 - Article
C2 - 33426888
AN - SCOPUS:85099939071
SN - 1044-0305
VL - 32
SP - 590
EP - 596
JO - Journal of the American Society for Mass Spectrometry
JF - Journal of the American Society for Mass Spectrometry
IS - 2
ER -