Defect inspection of actuator lenses using swept-source optical coherence tomography

Jaeyul Lee, Muhammad Faizan Shirazi, Kibeom Park, Mansik Jeon, Jeehyun Kim

Research output: Contribution to journalArticlepeer-review

7 Scopus citations

Abstract

Actuator lens industries have gained an enormous interest with the enhancement of various latest communication devices, such as mobile phone and notebooks. The quality of the aforementioned devices can be degraded due to the internal defects of actuator lenses. Therefore, in this study, we implemented swept-source optical coherence tomography (SS-OCT) system to inspect defects of actuator lenses. Owing to the high-resolution of the SS-OCT system, defected foreign substances between the actuator lenses, defective regions of lenses and surface stains were more clearly distinguished through three-dimensional (3D) and two-dimensional (2D) cross-sectional OCT images. Therefore, the implemented SS-OCT system can be considered as a potential application to defect inspection of actuator lens.

Original languageEnglish
Pages (from-to)403-409
Number of pages7
JournalOptical Review
Volume25
Issue number3
DOIs
StatePublished - 1 Jun 2018

Keywords

  • Actuator lens
  • Defect identification
  • Industrial lens inspection
  • Optical coherence tomography

Fingerprint

Dive into the research topics of 'Defect inspection of actuator lenses using swept-source optical coherence tomography'. Together they form a unique fingerprint.

Cite this