T1 - Determination of benidipine in human plasma using liquid chromatography-tandem mass spectrometry
AU - Kang, Wonku
AU - Yun, Hwi Yeol
AU - Liu, Kwang Hyeon
AU - Kwon, Kwang Il
AU - Shin, Jae Gook
PY - 2004/6/15
Y1 - 2004/6/15
N2 - We developed a method for determining benidipine, a dihydropyridine analogue calcium-channel blocker, in plasma using liquid chromatography-tandem mass spectrometry (LC-MS-MS). Benidipine and benidipine-d5, an internal standard, were extracted from plasma using diethyl ether in the presence of 5 M NaOH. After drying the organic layer, the residue was reconstituted in acetonitrile and injected onto a reversed-phase C18 column. The isocratic mobile phase (acetonitrile-5 mM ammonium acetate, 90:10, v/v) was eluted at 0.2 ml/min. The ion transitions monitored in multiple reaction-monitoring mode were m/z 506-174 for benidipine and m/z 511-179 for the internal standard. The coefficient of variation of the assay precision was less than 13%, and the accuracy exceeded 92%, except at the limit of quantification, 0.05 ng/ml with 1 ml of plasma, when it was 85%. This method was used to measure the benidipine concentration in plasma from healthy subjects after a single 4-mg oral dose of benidipine. This method is a very simple, sensitive, and accurate way to determine the plasma benidipine concentration.
AB - We developed a method for determining benidipine, a dihydropyridine analogue calcium-channel blocker, in plasma using liquid chromatography-tandem mass spectrometry (LC-MS-MS). Benidipine and benidipine-d5, an internal standard, were extracted from plasma using diethyl ether in the presence of 5 M NaOH. After drying the organic layer, the residue was reconstituted in acetonitrile and injected onto a reversed-phase C18 column. The isocratic mobile phase (acetonitrile-5 mM ammonium acetate, 90:10, v/v) was eluted at 0.2 ml/min. The ion transitions monitored in multiple reaction-monitoring mode were m/z 506-174 for benidipine and m/z 511-179 for the internal standard. The coefficient of variation of the assay precision was less than 13%, and the accuracy exceeded 92%, except at the limit of quantification, 0.05 ng/ml with 1 ml of plasma, when it was 85%. This method was used to measure the benidipine concentration in plasma from healthy subjects after a single 4-mg oral dose of benidipine. This method is a very simple, sensitive, and accurate way to determine the plasma benidipine concentration.
KW - Benidipine
UR - http://www.scopus.com/inward/record.url?scp=2342537100&partnerID=8YFLogxK
U2 - 10.1016/j.jchromb.2004.03.023
DO - 10.1016/j.jchromb.2004.03.023
M3 - Article
C2 - 15135106
AN - SCOPUS:2342537100
SN - 1570-0232
VL - 805
SP - 311
EP - 314
JO - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
JF - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
IS - 2
ER -