Development of a fast solid-state high-resolution density profile reflectometer system on the DIII-D tokamak

K. W. Kim, E. J. Doyle, T. L. Rhodes, W. A. Peebles, C. L. Rettig, N. C. Luhmann

Research output: Contribution to journalArticlepeer-review

42 Scopus citations

Abstract

A new fast-sweep, broadband frequency-modulated reflectometer on the DIII-D tokamak has produced routine, reliable density profiles with high spatial (≤1 cm) and temporal resolution (∼100 μs). The system utilizes a solid-state microwave source and an active quadrupler, covering the full Q-band (33-50 GHz) and providing high output power (20-60 mW). The rf source frequency is linearized using an arbitrary function generator and the temperature of the source is actively controlled to reduce rf frequency drifts. The system hardware allows the rf frequency to be swept fullband in 10 μs, but, due to digitization limits, the sweep time used currently is 75-100 μs. The reliability of the reconstructed profiles was improved by a combination of fast frequency sweep, which reduces density fluctuation effects on the measurements, and advanced signal analysis based on digital complex demodulation, which improves phase accuracy. The fast-sweep system has resolved fast-changing edge density profiles during edge localized modes with unprecedented resolution.

Original languageEnglish
Pages (from-to)466-469
Number of pages4
JournalReview of Scientific Instruments
Volume68
Issue number1
DOIs
StatePublished - Jan 1997

Fingerprint

Dive into the research topics of 'Development of a fast solid-state high-resolution density profile reflectometer system on the DIII-D tokamak'. Together they form a unique fingerprint.

Cite this