TY - JOUR
T1 - Effect of the Glide Path Establishment on the Torque Generation to the Files during Instrumentation
T2 - An In Vitro Measurement
AU - Kwak, Sang Won
AU - Ha, Jung Hong
AU - Cheung, Gary Shun Pan
AU - Kim, Hyeon Cheol
AU - Kim, Sung Kyo
N1 - Publisher Copyright:
© 2017 American Association of Endodontists
PY - 2018/3
Y1 - 2018/3
N2 - Introduction: The purpose of this study was to compare in vitro torque generation during instrumentation with or without glide path establishment. Methods: Endo-training resin blocks with J-shaped canals were randomly divided into 2 groups according to glide path establishment (with or without) and subdivided into 2 subgroups with shaping instruments (WaveOne [Dentsply Maillefer, Ballaigues, Switzerland] or WaveOne Gold [Dentsply Maillefer]) (n = 15). For the glide path–established group, the glide path was prepared using ProGlider (Dentsply Maillefer). During the instrumentation with WaveOne or WaveOne Gold, in vitro torque was measured. The acquired data were analyzed with software. The maximum torque and total torque (the sum of the generated torque) were calculated. The data were statistically evaluated using 2-way analysis of variance and the Duncan post hoc comparison to examine any correlation of torque generation with glide path establishment and nickel-titanium instruments. The significance level was set at 95%. Results: The generated total torque by WaveOne Gold was significantly reduced by glide path establishment (P <.05), whereas glide path establishment did not induce significant changes in the maximum torque for both file systems. WaveOne Gold with a glide path showed the lowest total torque generation among all groups (P <.05). WaveOne generated a higher maximum torque than WaveOne Gold regardless of the establishment of a glide path (P <.05). Conclusions: Under the limitations of this study, glide path establishment and the mechanical property of instruments have a significant influence on torque generation. It is recommended to create the glide path and use a flexible file to reduce torque generation and, consequently, the risk of file fracture and root dentin damage.
AB - Introduction: The purpose of this study was to compare in vitro torque generation during instrumentation with or without glide path establishment. Methods: Endo-training resin blocks with J-shaped canals were randomly divided into 2 groups according to glide path establishment (with or without) and subdivided into 2 subgroups with shaping instruments (WaveOne [Dentsply Maillefer, Ballaigues, Switzerland] or WaveOne Gold [Dentsply Maillefer]) (n = 15). For the glide path–established group, the glide path was prepared using ProGlider (Dentsply Maillefer). During the instrumentation with WaveOne or WaveOne Gold, in vitro torque was measured. The acquired data were analyzed with software. The maximum torque and total torque (the sum of the generated torque) were calculated. The data were statistically evaluated using 2-way analysis of variance and the Duncan post hoc comparison to examine any correlation of torque generation with glide path establishment and nickel-titanium instruments. The significance level was set at 95%. Results: The generated total torque by WaveOne Gold was significantly reduced by glide path establishment (P <.05), whereas glide path establishment did not induce significant changes in the maximum torque for both file systems. WaveOne Gold with a glide path showed the lowest total torque generation among all groups (P <.05). WaveOne generated a higher maximum torque than WaveOne Gold regardless of the establishment of a glide path (P <.05). Conclusions: Under the limitations of this study, glide path establishment and the mechanical property of instruments have a significant influence on torque generation. It is recommended to create the glide path and use a flexible file to reduce torque generation and, consequently, the risk of file fracture and root dentin damage.
KW - Glide path
KW - in vitro torque
KW - nickel-titanium instrument
KW - torsional resistance
KW - torsional stress
UR - http://www.scopus.com/inward/record.url?scp=85035330817&partnerID=8YFLogxK
U2 - 10.1016/j.joen.2017.09.016
DO - 10.1016/j.joen.2017.09.016
M3 - Article
C2 - 29203073
AN - SCOPUS:85035330817
SN - 0099-2399
VL - 44
SP - 496
EP - 500
JO - Journal of Endodontics
JF - Journal of Endodontics
IS - 3
ER -