Abstract
This study examined the effectiveness of a field-type liquid cooling vest (LCV) worn underneath an impermeable protective suit on heat strain during walking. Eight men walked for 60 min at a moderate speed (3.0 km/h) wearing the suit in a warm environment (33°C, 60% relative humidity) without (control, CON) or with the LCV. A smaller increase in rectal temperature was recorded in participants in the LCV than in the CON condition (37.6 ± 0.1°C vs. 37.9 ± 0.1°C, p<0.05). Walking while wearing the LCV reduced the level of physiological heat strain, as measured by the mean skin temperature (35.5 ± 0.1°C vs. 36.3 ± 0.1°C), chest sweat rate (13.5 ± 3.0 mg/cm2/ h vs. 16.6 ± 3.8 mg/cm2/h), chest cutaneous vascular conductance (349 ± 88% vs. 463 ± 122%), body weight loss (0.72 ± 0.05% vs. 0.93 ± 0.06%), and heart rate (101 ± 6 beats/min vs. 111 ± 7 beats/min) (p<0.05, for all comparisons). These changes were accompanied by a decrease in thermal sensation and discomfort. These results suggest that a field-type LCV attenuates exertional heat strain while wearing impermeable protective clothing.
Original language | English |
---|---|
Pages (from-to) | 63-71 |
Number of pages | 9 |
Journal | Industrial Health |
Volume | 58 |
Issue number | 1 |
DOIs | |
State | Published - 2020 |
Keywords
- Core temperature
- Heat stress
- Hypohydration
- Microclimate cooling
- Thermal strain