TY - JOUR
T1 - Facile Preparation of Ionic Liquid-coated Copper Nanowire-modified Carbon Paste Electrode for Electrochemical Detection of Etilefrine Drug
AU - Venkateswarlu, Sada
AU - Venu, Manthrapudi
AU - Reddy, Yenegu Veera Manohara
AU - Sravani, Bathinapatla
AU - Mallikarjuna, K.
AU - Yoon, Minyoung
AU - Madhavi, G.
N1 - Publisher Copyright:
© 2019 Korean Chemical Society, Seoul & Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim
PY - 2019/6
Y1 - 2019/6
N2 - A carbon paste electrode (CPE)/Cu nanowire (Cu NW)/poly(1-ethyl-3-methylimidazolium methyl sulfate) based sensor was successfully fabricated by the electro-polymerization of 1-ethyl-3-methylimidazolium methyl sulfate (EMIMS) onto the surface of Cu nanowires-modified carbon paste electrode. The morphology and chemical nature of Cu NWs were characterized by FTIR, FE-SEM, TEM, XRD techniques. The CPE/CuNWs/poly(EMIMS) showed an electrocatalytic activity toward the determination of etilefrine hydrochloride (ET-HCl) in the 0.11 M buffer solution of phosphate at pH 7.0. The CPE/CuNWs/poly(EMIMS) showed an excellent limit of detection (LOD) 2.3 μM over the linear dynamic range of 0.1 to 1.3 μM. The prepared CPE/CuNWs/poly(EMIMS) has exhibited high stability, good sensitivity, and low detection limit for the determination of ET-HCl. The validity of this advanced method was checked by applying in the blood plasma samples, with satisfactory results. This novel CPE/CuNWs/poly(EMIMS) can be an attractive material for the applications in biomedical and sensor fields.
AB - A carbon paste electrode (CPE)/Cu nanowire (Cu NW)/poly(1-ethyl-3-methylimidazolium methyl sulfate) based sensor was successfully fabricated by the electro-polymerization of 1-ethyl-3-methylimidazolium methyl sulfate (EMIMS) onto the surface of Cu nanowires-modified carbon paste electrode. The morphology and chemical nature of Cu NWs were characterized by FTIR, FE-SEM, TEM, XRD techniques. The CPE/CuNWs/poly(EMIMS) showed an electrocatalytic activity toward the determination of etilefrine hydrochloride (ET-HCl) in the 0.11 M buffer solution of phosphate at pH 7.0. The CPE/CuNWs/poly(EMIMS) showed an excellent limit of detection (LOD) 2.3 μM over the linear dynamic range of 0.1 to 1.3 μM. The prepared CPE/CuNWs/poly(EMIMS) has exhibited high stability, good sensitivity, and low detection limit for the determination of ET-HCl. The validity of this advanced method was checked by applying in the blood plasma samples, with satisfactory results. This novel CPE/CuNWs/poly(EMIMS) can be an attractive material for the applications in biomedical and sensor fields.
KW - 1-Ethyl-3-methylimidazolium methyl sulfate
KW - Copper nanowires
KW - Cyclic voltammetry
KW - Electrochemical sensor
KW - Etilefrine hydrochloride
UR - http://www.scopus.com/inward/record.url?scp=85065341293&partnerID=8YFLogxK
U2 - 10.1002/bkcs.11734
DO - 10.1002/bkcs.11734
M3 - Article
AN - SCOPUS:85065341293
SN - 0253-2964
VL - 40
SP - 560
EP - 565
JO - Bulletin of the Korean Chemical Society
JF - Bulletin of the Korean Chemical Society
IS - 6
ER -