Skip to main navigation Skip to search Skip to main content

Fast and Efficient Birdcage Coil Design Process for High Field MRI System by Combining Equivalent Circuit Model and 3D Electromagnetic Simulation

  • Sheikh Faisal Ahmad
  • , Young Cheol Kim
  • , Ick Chang Choi
  • , Sungwoo Choi
  • , Tae Gu Kim
  • , Changmin Ahn
  • , Hyun Deok Kim
  • Kyungpook National University

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

4 Scopus citations

Abstract

A novel method has been established to mitigate the complexity of a birdcage coil design process for use in a MRI (Magnetic Resonance Imaging) system. It can reduce the time consumptions of the typical coil design process based on 3D (three-dimensional) simulations. The method combines an equivalent circuit model and a 3D electromagnetic simulation. It makes it possible to understand the coil properties intuitively and to solve the major engineering problems by using just the circuit model not by using the complex 3D simulation. The concept of the dominant resonance path length of the coil has also been introduced, which facilitates the design process by considering the skin effect of the coil. We have verified that the skin effect of the birdcage coil can be evaluated through a simple circular loop circuit instead of the whole 3D geometry. Base on the design proposed method, we also have successfully demonstrated that the birdcage coil based on a FPCB (Flexible Printed Circuit board) technique can be used in high filed (3.0 T and 4.7 T) MRI systems for small animal NMR (Nuclear Magnetic Resonance) imaging.

Original languageEnglish
Title of host publicationAMS 2017 - Asia Modelling Symposium 2017 and 11th International Conference on Mathematical Modelling and Computer Simulation
EditorsZuwairie Ibrahim, David Al-Dabass, Mohd Ibrahim Shapiai
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages188-194
Number of pages7
ISBN (Print)9781538637524
DOIs
StatePublished - 1 Aug 2018
Event2017 Asia Modelling Symposium, AMS 2017 and 11th International Conference on Mathematical Modelling and Computer Simulation - Kota Kinabalu, Sabah, Malaysia
Duration: 4 Dec 20176 Dec 2017

Publication series

NameAMS 2017 - Asia Modelling Symposium 2017 and 11th International Conference on Mathematical Modelling and Computer Simulation

Conference

Conference2017 Asia Modelling Symposium, AMS 2017 and 11th International Conference on Mathematical Modelling and Computer Simulation
Country/TerritoryMalaysia
CityKota Kinabalu, Sabah
Period4/12/176/12/17

Keywords

  • 3D eletomagentic simulation
  • birdcage coil
  • equivalent circuit mode
  • MRI system
  • skin effect

Fingerprint

Dive into the research topics of 'Fast and Efficient Birdcage Coil Design Process for High Field MRI System by Combining Equivalent Circuit Model and 3D Electromagnetic Simulation'. Together they form a unique fingerprint.

Cite this