Abstract
The dual three-phase permanent magnet synchronous motor drive system consist of dual three-phase inverter and dual three-phase stator winding set in motor. The dual drive-mode that utilizes dual stator winding set and dual three-phase inverter is commonly used for general operation. However, in order to improve the total efficiency of the drive system, it is also necessary to consider the efficiency of a single drive mode such as a conventional three-phase drive. In this paper, the high efficiency drive strategy of dual three-phase permanent magnet synchronous motor is proposed to utilize the highest efficiency point in each drive mode. Based on the analysis about efficiency for each drive-mode, the drive-mode changeover is proposed. The experimental results validate the proposed high efficiency drive strategy.
| Original language | English |
|---|---|
| Pages (from-to) | 881-886 |
| Number of pages | 6 |
| Journal | Transactions of the Korean Institute of Electrical Engineers |
| Volume | 69 |
| Issue number | 6 |
| DOIs | |
| State | Published - Jun 2020 |
Keywords
- Drive-mode changeover
- Dual three-phase
- High efficiency drive
- Permanent magnet synchronous motor
Fingerprint
Dive into the research topics of 'High efficiency drive strategy of dual three-phase permanent magnet synchronous motor'. Together they form a unique fingerprint.Cite this