Abstract
The influence of the Xe (15%) and He (70%) fractions on the discharge and driving characteristics was compared in 50-in. full-HD plasma-display panels. The same improvement in the luminous efficacy was obtained when increasing either the Xe or He fraction. However, the discharge current with a high He fraction was smaller than that with a high Xe fraction. While the breakdown voltage was hardly influenced by an increase in the He fraction, it was significantly changed when increasing the Xe fraction. The formative and statistical time lags were only slightly changed with a high He fraction, yet significantly increased with a high Xe fraction. In addition, the relatively low luminance and driving-margin characteristics with a high He fraction were compensated for by controlling the capacitance of the upper dielectric layer.
Original language | English |
---|---|
Pages (from-to) | 61-68 |
Number of pages | 8 |
Journal | Journal of the Society for Information Display |
Volume | 17 |
Issue number | 1 |
DOIs | |
State | Published - Jan 2009 |
Keywords
- Address discharge delay
- Driving margin
- Full-HD PDP
- High helium
- Luminous efficacy