Improvement of luminous efficiency using high helium content in full-HD plasma-display panels

Ki Hyung Park, Heung Sik Tae, Hyeong Seol Jeong, Min Hur, Eun Gi Heo

Research output: Contribution to journalArticlepeer-review

8 Scopus citations

Abstract

The influence of the Xe (15%) and He (70%) fractions on the discharge and driving characteristics was compared in 50-in. full-HD plasma-display panels. The same improvement in the luminous efficacy was obtained when increasing either the Xe or He fraction. However, the discharge current with a high He fraction was smaller than that with a high Xe fraction. While the breakdown voltage was hardly influenced by an increase in the He fraction, it was significantly changed when increasing the Xe fraction. The formative and statistical time lags were only slightly changed with a high He fraction, yet significantly increased with a high Xe fraction. In addition, the relatively low luminance and driving-margin characteristics with a high He fraction were compensated for by controlling the capacitance of the upper dielectric layer.

Original languageEnglish
Pages (from-to)61-68
Number of pages8
JournalJournal of the Society for Information Display
Volume17
Issue number1
DOIs
StatePublished - Jan 2009

Keywords

  • Address discharge delay
  • Driving margin
  • Full-HD PDP
  • High helium
  • Luminous efficacy

Fingerprint

Dive into the research topics of 'Improvement of luminous efficiency using high helium content in full-HD plasma-display panels'. Together they form a unique fingerprint.

Cite this