Abstract
The effects of the temporal and permanent bright image stickings were examined under variable panel working gas pressure in the 42-in. ac-PDP with a high Xe (11 %) content. In the cells with and without temporal and permanent bright image stickings, the display luminance, firing voltage, and Vt closed curve were measured relative to the working gas pressure. With a decrease in the working gas pressure, the temporal bright image sticking was observed to be reduced, whereas the permanent bright image sticking was observed to be deteriorated.
Original language | English |
---|---|
Pages (from-to) | 1617-1620 |
Number of pages | 4 |
Journal | Proceedings of International Meeting on Information Display |
Volume | 8 |
State | Published - 2008 |
Event | 8th International Meeting on Information Display - International Display Manufacturing Conference 2008 and Asia Display 2008, IMID/IDMC/ASIA DISPLAY 2008 - Ilsan, Korea, Republic of Duration: 13 Oct 2008 → 17 Oct 2008 |
Keywords
- AC-PDP
- Image sticking
- MgO
- Pressure
- Re-deposition