Skip to main navigation Skip to search Skip to main content

Interturn fault tolerant driving algorithm of IPMSMs: Maximum torque control within power loss limit

  • Kyungpook National University

Research output: Contribution to journalArticlepeer-review

Abstract

The winding of the motor stator coil is broken due to external stress and various factors. If the proper current is not injected when interturn fault(ITF) occurs, the fault can easily be expanded and the motor can be finally destroyed, resulting in many problems with time costs and safety. In this paper, the power loss limit concept, which is the inherent durability of each motor, is applied to secure safety by controlling the total power loss of the motor within the limits. So, we propose an algorithm that can control maximum torque per minimum power loss based on constant torque curve and power loss limit. To verify the proposed method, the simulation and experimental results with an Interior permanent magnet synchronous motor(IPMSM) having an ITF are shown.

Original languageEnglish
Pages (from-to)52-60
Number of pages9
JournalTransactions of the Korean Institute of Electrical Engineers
Volume67
Issue number1
DOIs
StatePublished - Jan 2018

Keywords

  • Interturn fault
  • Maximum torque per minimum power loss control
  • Power loss limit

Fingerprint

Dive into the research topics of 'Interturn fault tolerant driving algorithm of IPMSMs: Maximum torque control within power loss limit'. Together they form a unique fingerprint.

Cite this