Investigation of winding connections for fault-tolerant of MW class offshore wind generator with Dual 3-Phase system and modular

Research output: Contribution to journalArticlepeer-review

Abstract

This paper presents a new winding topology for MW class offshore wind generator having modular and dual 3-phase. Based on proposed simplified relationship between magnetic flux and phase current in the air gap, several new windings for modular and dual 3-phase are made. In case of one inverter operation or faulty operation, the proposed model can have balanced 3-phase induced voltage whereas the conventional generator with modular winding has unbalanced induced voltage, which can be important issue in offshore generator. The model was applied into 6MW prototype machine with dual 3-phase. Using finite element analysis, induced voltage, inductance were investigated. The results show that the proposed modular winding can be applicable to dual inverter system with electrically balanced voltase.

Original languageEnglish
Pages (from-to)1108-1114
Number of pages7
JournalTransactions of the Korean Institute of Electrical Engineers
Volume62
Issue number8
DOIs
StatePublished - Aug 2013

Keywords

  • Dual 3-phase
  • Modular winding
  • Pm machine

Fingerprint

Dive into the research topics of 'Investigation of winding connections for fault-tolerant of MW class offshore wind generator with Dual 3-Phase system and modular'. Together they form a unique fingerprint.