Mechanistic study on lowering the sensitivity of positive atmospheric pressure photoionization mass spectrometric analyses: Size-dependent reactivity of solvent clusters

Research output: Contribution to journalArticlepeer-review

15 Scopus citations

Abstract

Rationale Understanding the mechanism of atmospheric pressure photoionization (APPI) is important for studies employing APPI liquid chromatography/mass spectrometry (LC/MS). In this study, the APPI mechanism for polyaromatic hydrocarbon (PAH) compounds dissolved in toluene and methanol or water mixture was investigated by use of MS analysis and quantum mechanical simulation. In particular, four different mechanisms that could contribute to the signal reduction were considered based on a combination of MS data and quantum mechanical calculations. Methods The APPI mechanism is clarified by combining MS data and density functional theory (DFT) calculations. To obtain MS data, a positive-mode (+) APPI Q Exactive Orbitrap mass spectrometer was used to analyze each solution. DFT calculations were performed using the general atomic and molecular electronic structure system (GAMESS). Results The experimental results indicated that methanol significantly reduced the signal in (+) APPI, but no significative signal reduction was observed when water was used as a co-solvent with toluene. The signal reduction is more significant especially for molecular ions than for protonated ions. Therefore, important information about the mechanism of methanol-induced signal reduction in (+) APPI-MS can be gained due its negative impact on APPI efficiency. Conclusions The size-dependent reactivity of methanol clusters ((CH3OH)n, n1-8) is an important factor in determining the sensitivity of (+) APPI-MS analyses. Clusters can compete with toluene radical ions for electrons. The reactivity increases as the sizes of the methanol clusters increase and this effect can be caused by the size-dependent ionization energy of the solvent clusters. The resulting increase in cluster reactivity explains the flow rate and temperature-dependent signal reduction observed in the analytes. Based on the results presented here, minimizing the sizes of methanol clusters can improve the sensitivity of LC/(+)-APPI-MS.

Original languageEnglish
Pages (from-to)2095-2101
Number of pages7
JournalRapid Communications in Mass Spectrometry
Volume29
Issue number21
DOIs
StatePublished - 15 Nov 2015

Fingerprint

Dive into the research topics of 'Mechanistic study on lowering the sensitivity of positive atmospheric pressure photoionization mass spectrometric analyses: Size-dependent reactivity of solvent clusters'. Together they form a unique fingerprint.

Cite this