TY - GEN
T1 - Miniaturized focused ultrasound transducers for intravascular therapies
AU - Kim, Jinwook
AU - Wu, Huaiyu
AU - Jiang, Xiaoning
N1 - Publisher Copyright:
© Copyright 2017 ASME.
PY - 2017
Y1 - 2017
N2 - Intravascular ultrasound approach has shown its advantages for thrombectomy. Catheter-directed ultrasound techniques have realized safe therapies by suppressing mechanical contact and penetration of excessive ultrasound energy through the tissue. One limitation of this approach is the lack of the sufficient ultrasound energy for fast thrombectomy because typical catheter-mounted transducers have high-frequency and low acoustic power. In this work, we aim to resolve this problem by designing miniaturized focused ultrasound transducers for improved therapeutic efficacy, which can generate low-frequency, sufficient pressure output within the confined insonation beam. This study builds upon our previous initial design of sub-megahertz, forward-looking, focused ultrasound transducers for preliminary in vitro study on microbubble-mediated thrombolysis. 650 kHz, forward-looking, concave-aperture ultrasound transducers were designed and mounted on 5-6 F catheters. The effect of design factors including aperture diameter, radius-of-curvature, and concave lens acoustic impedance on focusing performance were analyzed by using finite element analysis. Although the theoretical prerequisites for ideal beam focusing were not fulfilled due to the spatial limitation, the simulation results showed that practical design of the concave lens with the small geometrical aperture still enables to generate confined beam with a reasonable focal gain. Experimental validation results confirmed that the focal gain of 9 dB can be achievable. The measured transmitting sensitivity of the concave aperture transducer is 22.5 kPa/Vpp.
AB - Intravascular ultrasound approach has shown its advantages for thrombectomy. Catheter-directed ultrasound techniques have realized safe therapies by suppressing mechanical contact and penetration of excessive ultrasound energy through the tissue. One limitation of this approach is the lack of the sufficient ultrasound energy for fast thrombectomy because typical catheter-mounted transducers have high-frequency and low acoustic power. In this work, we aim to resolve this problem by designing miniaturized focused ultrasound transducers for improved therapeutic efficacy, which can generate low-frequency, sufficient pressure output within the confined insonation beam. This study builds upon our previous initial design of sub-megahertz, forward-looking, focused ultrasound transducers for preliminary in vitro study on microbubble-mediated thrombolysis. 650 kHz, forward-looking, concave-aperture ultrasound transducers were designed and mounted on 5-6 F catheters. The effect of design factors including aperture diameter, radius-of-curvature, and concave lens acoustic impedance on focusing performance were analyzed by using finite element analysis. Although the theoretical prerequisites for ideal beam focusing were not fulfilled due to the spatial limitation, the simulation results showed that practical design of the concave lens with the small geometrical aperture still enables to generate confined beam with a reasonable focal gain. Experimental validation results confirmed that the focal gain of 9 dB can be achievable. The measured transmitting sensitivity of the concave aperture transducer is 22.5 kPa/Vpp.
UR - http://www.scopus.com/inward/record.url?scp=85041014509&partnerID=8YFLogxK
U2 - 10.1115/IMECE2017-72426
DO - 10.1115/IMECE2017-72426
M3 - Conference contribution
AN - SCOPUS:85041014509
T3 - ASME International Mechanical Engineering Congress and Exposition, Proceedings (IMECE)
BT - Biomedical and Biotechnology Engineering
PB - American Society of Mechanical Engineers (ASME)
T2 - ASME 2017 International Mechanical Engineering Congress and Exposition, IMECE 2017
Y2 - 3 November 2017 through 9 November 2017
ER -