Abstract
In this paper, a new reset driving waveform is proposed to widen a driving margin under the low address voltage in AC-PDPs, The proposed reset waveform can alter the wall charge distribution between the X-Y electrodes by applying the X-ramp bias(ΔVx) prior to an address-period, thus resulting in lowering the minimum level of the scan pulse(ΔVy) during an address-period without a misfiring discharge in off-cells. As a result of adopting the proposed reset waveform, the address discharge time delay is reduced about by 200 ns at an address voltage of 35 V and the related dynamic driving margin is observed to be wide under a low address voltage condition, and its related phenomenon is examined by the Vt close-curve method.
Original language | English |
---|---|
Pages | 1757-1760 |
Number of pages | 4 |
State | Published - 2006 |
Event | 13th International Display Workshops, IDW '06 - Otsu, Japan Duration: 6 Dec 2006 → 6 Dec 2006 |
Conference
Conference | 13th International Display Workshops, IDW '06 |
---|---|
Country/Territory | Japan |
City | Otsu |
Period | 6/12/06 → 6/12/06 |