Abstract
Optical-resolution photoacoustic microscopy (OR-PAM) becomes a premier microscopic imaging tool in biomedicine because it provides agent-free optical absorption information in tissues. By tightly focusing light to a spot, a significantly improved lateral resolution can be achieved in OR-PAM. The focal spot size is typically determined by the numerical aperture of the used objective lens. Here, we demonstrate objective-free OR-PAM using a fiber optic Bessel beam generator. In this approach, no objective lens is required and, beneficially, the complexities of conventional OR-PAM systems can be greatly relieved. We have obtained photoacoustic images of a carbon fiber with a diameter of ≪6 μm, whose lateral resolution was measured to be better than 6 to 7 μm.
| Original language | English |
|---|---|
| Article number | 010501 |
| Journal | Journal of Biomedical Optics |
| Volume | 18 |
| Issue number | 1 |
| DOIs | |
| State | Published - 2013 |
Keywords
- Bessel beam
- fiber optics
- focus free imaging
- optical-resolution photoacoustic microscopy
Fingerprint
Dive into the research topics of 'Objective-free optical-resolution photoacoustic microscopy'. Together they form a unique fingerprint.Cite this