TY - JOUR
T1 - Osseointegration of two different phosphate ion-containing titanium oxide surfaces in rabbit cancellous bone
AU - Park, Jin Woo
PY - 2013/8
Y1 - 2013/8
N2 - Objective: This study assessed the osseointegration of grit-blasted titanium (Ti) implants with a hydrophilic phosphate ion-incorporated oxide surface in rabbit cancellous bone, and compared its bone healing with commercially available phosphate-incorporated clinical implants obtained by micro-arc oxidation (TiUnite, TU implant). Material and methods: The hydrophilic phosphate-incorporated Ti surface (P implant) was produced by hydrothermal treatment on grit-blasted moderately rough-surfaced clinical implant. The TU surface was used as a control. The surface characteristics were evaluated by field emission-scanning electron microscopy, X-ray photoelectron spectroscopy, optical profilometry, and inductively coupled plasma-atomic emission spectroscopy (ICP-AES). Thirty-two threaded implants with lengths of 10 and 3.3 mm diameter (16 P implants and 16 TU implants) were placed in the femoral condyles of 16 New Zealand White rabbits. Histomorphometric analysis, removal torque tests, and surface analysis of the torque-tested implants were performed 4 weeks after implantation. Results: The P and TU implants displayed micro-rough surface features with similar Ra values at the micron-scale. ICP-AES analysis revealed that both the P and TU implants released phosphate ions into the solution. The torque-tested P and TU implants exhibited a considerable quantity of bone attached to the surface. The P implants exhibited significantly higher bone-implant contact percentages, both in terms of the all threads region and the total lateral length of implants compared with the TU implants (P < 0.01), but no statistical difference was found for the removal torque values. Conclusion: These results suggest that the phosphate-incorporated Ti oxide surface obtained by hydrothermal treatment achieves rapid osseointegration in cancellous bone by increasing the degree of bone-implant contact.
AB - Objective: This study assessed the osseointegration of grit-blasted titanium (Ti) implants with a hydrophilic phosphate ion-incorporated oxide surface in rabbit cancellous bone, and compared its bone healing with commercially available phosphate-incorporated clinical implants obtained by micro-arc oxidation (TiUnite, TU implant). Material and methods: The hydrophilic phosphate-incorporated Ti surface (P implant) was produced by hydrothermal treatment on grit-blasted moderately rough-surfaced clinical implant. The TU surface was used as a control. The surface characteristics were evaluated by field emission-scanning electron microscopy, X-ray photoelectron spectroscopy, optical profilometry, and inductively coupled plasma-atomic emission spectroscopy (ICP-AES). Thirty-two threaded implants with lengths of 10 and 3.3 mm diameter (16 P implants and 16 TU implants) were placed in the femoral condyles of 16 New Zealand White rabbits. Histomorphometric analysis, removal torque tests, and surface analysis of the torque-tested implants were performed 4 weeks after implantation. Results: The P and TU implants displayed micro-rough surface features with similar Ra values at the micron-scale. ICP-AES analysis revealed that both the P and TU implants released phosphate ions into the solution. The torque-tested P and TU implants exhibited a considerable quantity of bone attached to the surface. The P implants exhibited significantly higher bone-implant contact percentages, both in terms of the all threads region and the total lateral length of implants compared with the TU implants (P < 0.01), but no statistical difference was found for the removal torque values. Conclusion: These results suggest that the phosphate-incorporated Ti oxide surface obtained by hydrothermal treatment achieves rapid osseointegration in cancellous bone by increasing the degree of bone-implant contact.
KW - Histomorphometry
KW - Osseointegration
KW - Phosphate ion
KW - Surface modification
KW - Titanium implant
UR - http://www.scopus.com/inward/record.url?scp=84880699951&partnerID=8YFLogxK
U2 - 10.1111/j.1600-0501.2011.02406.x
DO - 10.1111/j.1600-0501.2011.02406.x
M3 - Article
C2 - 22251085
AN - SCOPUS:84880699951
SN - 0905-7161
VL - 24
SP - 145
EP - 151
JO - Clinical Oral Implants Research
JF - Clinical Oral Implants Research
IS - A100
ER -