Abstract
In this study, the performance of five-DOF motion in ultra-precision linear stage is evaluated accurately by extending the application of the ISO 230-2 International Standard, which is focused only on the linear displacement motion of a linear stage. The bidirectional accuracy and bidirectional repeatability of positioning in five-DOF motion are calculated by measured geometric errors. Five geometric errors except for the linear displacement error of a linear stage are measured simultaneously using the optimal measurement system, which is designed to enhance the standard uncertainty of the estimated geometric errors. The geometric errors are in good agreement with those from the laser interferometer. In addition, the confidence intervals of the performances are determined by the uncertainties of the equipment used in the experiment.
Original language | English |
---|---|
Pages (from-to) | 129-134 |
Number of pages | 6 |
Journal | International Journal of Precision Engineering and Manufacturing |
Volume | 15 |
Issue number | 1 |
DOIs | |
State | Published - Jan 2014 |
Keywords
- Geometric error
- ISO 230-2 International standard
- Performance evaluation
- Reference coordinate system
- Ultra-precision linear stage