Performance evaluation of five-DOF motion in ultra-precision linear stage

Kwang Il Lee, Jae Chang Lee, Seung Han Yang

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

In this study, the performance of five-DOF motion in ultra-precision linear stage is evaluated accurately by extending the application of the ISO 230-2 International Standard, which is focused only on the linear displacement motion of a linear stage. The bidirectional accuracy and bidirectional repeatability of positioning in five-DOF motion are calculated by measured geometric errors. Five geometric errors except for the linear displacement error of a linear stage are measured simultaneously using the optimal measurement system, which is designed to enhance the standard uncertainty of the estimated geometric errors. The geometric errors are in good agreement with those from the laser interferometer. In addition, the confidence intervals of the performances are determined by the uncertainties of the equipment used in the experiment.

Original languageEnglish
Pages (from-to)129-134
Number of pages6
JournalInternational Journal of Precision Engineering and Manufacturing
Volume15
Issue number1
DOIs
StatePublished - Jan 2014

Keywords

  • Geometric error
  • ISO 230-2 International standard
  • Performance evaluation
  • Reference coordinate system
  • Ultra-precision linear stage

Fingerprint

Dive into the research topics of 'Performance evaluation of five-DOF motion in ultra-precision linear stage'. Together they form a unique fingerprint.

Cite this