Abstract
We fabricated an AC-coupled single-sided silicon strip sensor and an DC-coupled double-sided silicon strip sensor on a 5-in. 380-μm-thick wafer. The single-sided strip sensor has a size of 3.2 cm × 3.2 cm and 64 implanted and readout strips with a strip pitch of 500 μm On the other hand, the double-sided strip sensor has an active size of 5.6 cm × 3.0 cm and 512 readout strips with a strip pitch of 50 μm. Two low-noise analog ASIC VA1and VA1A chips were used for signal readout of the single-sided strip and the double-sided strip sensors, respectively. The data acquisition system was based on a 12-bit 64-MHz Flash analog-to-digital converter (FADC) and control software for the PC-Linux platform. The signal-to-noise ratios of the sensor were measured with radioactive sources and a 45-MeV proton beam of the MC-50 cyclotron at Korea Institute of Radiological and Medical Sciences (KIRAMS). The performance results of the manufactured AC-coupled single-sided silicon strip detector and DC-coupled double-sided silicon strip detector are presented.
| Original language | English |
|---|---|
| Pages (from-to) | 828-831 |
| Number of pages | 4 |
| Journal | Journal of the Korean Physical Society |
| Volume | 52 |
| Issue number | 3 PART 1 |
| DOIs | |
| State | Published - Mar 2008 |
Keywords
- Proton beam
- Radioactive source
- Signal-to-noise ratio
- Silicon strip detector
- VA1
- VA1TA
Fingerprint
Dive into the research topics of 'Performance tests of a silicon strip detector with radioactive sources and proton beam'. Together they form a unique fingerprint.Cite this