Precontoured Plate Fixation for Incomplete Atypical Diaphyseal Fracture of Femur using Three-Dimensional Printing Rapid Prototyping: Two Cases Reports

Heejae Won, Seung Hoon Baek, Cheol Hwan Kim, Dong Hyeon Kim, Jee Wook Yoon, Shin Yoon Kim

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

Background: Reconstruction intramedullary nail spanning the whole length of the femur has been the gold standard treatment for complete atypical diaphyseal fractures of the femur (ADF). However, in cases of incomplete ADF combined with severe bowing, this approach might have complications and lead to iatrogenic complete fracture. We report two cases of incomplete ADF with severe bowing using a precontoured plate (PCP) after rapid prototyping (RP) of the deformed femurs with three-dimensional printing (3DP) technology. Case presentation: Two patients presented with gradually worsening thigh pain, especially during walking. The patients had been using bisphosphonates for 4 and 10 years, respectively. Radiography showed an incomplete fracture in the lateral cortex of the right femur shaft. The lateral bowing angles measured in the affected femurs were 15° and 14°, and the anterior bowing angles were 20° and 16°, respectively. In bone scans, both patients showed hot uptake in the right mid-shaft of the femur. Preoperatively, the affected femur of the patient was reconstructed by 3DP RP using CT, and the plate was bent to the shape of the bone model. The ADF was fixed with a PCP using the minimally invasive plate osteosynthesis technique. Both patients were encouraged to start full weight-bearing and return to their preinjury activity level in daily life immediately after surgery. At 2 years postoperatively, radiography showed healing of the fracture site without recurrence of thigh pain and implant-related problems. Conclusion: Although intramedullary nailing is the standard surgical treatment for complete ADF, PCP using 3DP RP could be an effective treatment option for incomplete ADF with severely curved femur.

Original languageEnglish
Pages (from-to)353-359
Number of pages7
JournalOrthopaedic surgery
Volume13
Issue number1
DOIs
StatePublished - Feb 2021

Keywords

  • Diaphyseal femoral fracture
  • Incomplete fracture
  • Minimally invasive surgery
  • Precontoured plate
  • Three-dimensional printing

Fingerprint

Dive into the research topics of 'Precontoured Plate Fixation for Incomplete Atypical Diaphyseal Fracture of Femur using Three-Dimensional Printing Rapid Prototyping: Two Cases Reports'. Together they form a unique fingerprint.

Cite this