Robust numerical analysis based design of the thermal vapor compressor shape parameters for multi-effect desalination plants

Research output: Contribution to journalArticlepeer-review

18 Scopus citations

Abstract

A thermal vapor compressor (TVC) that is to be adopted for use in a multi-effect desalination (MED) plant isdesigned with a high entraining performance and is appraised with respect to its stability robustness of operating inthe double choking region under abrupt changes in the operating conditions such as the motive and suction steampressures which can be easily caused due to external disturbances. Firstly the shape of the TVC having a highentraining performance is determined by performing an iterative CFD analysis for the various shape conditionsunder the given design pressure conditions. Then the entrainment ratio of the TVC is determined numerically in acertain fluctuating range of the operational pressure. Alteration patterns of the entrainment ratio are then consideredto assess whether the working of the TVC transfers to the unstable operating region or not.

Original languageEnglish
Pages (from-to)245-255
Number of pages11
JournalDesalination
Volume242
Issue number1-3
DOIs
StatePublished - Jun 2009

Keywords

  • CFD analysis
  • Entrainment ratio
  • Multi-effect desalination
  • Robust design
  • Thermal vapor compressor

Fingerprint

Dive into the research topics of 'Robust numerical analysis based design of the thermal vapor compressor shape parameters for multi-effect desalination plants'. Together they form a unique fingerprint.

Cite this