Abstract
Purpose: This study evaluated mid-term results of anterior cruciate ligament (ACL) reconstruction using the PINN-ACL CrossPin system that allowed for short graft fixation. Materials and Methods: Forty-three patients underwent single-bundle ACL reconstruction with a 4-strand semitendinosus tendon graft using the PINN-ACL CrossPin system. Femoral fixation was done using the PINN-ACL CrossPin system, and the tibial side was fixed with post-tie and a bioabsorbable interference screw. The mean follow-up period was 50 months. Evaluation was done using the Lachman test, pivot-shift test, International Knee Documentation Committee (IKDC) score and grade. Anterior displacement was assessed. Results: There was improvement in the Lachman test and pivot-shift test at final follow-up, form grade II (n=40) or III (n=3) to grade I (n=3) or 0 (n=40) and from grade I (n=20) or II (n=10) to grade I (n=8) or 0 (n=22), respectively. The mean IKDC score was 88.7, and grade A and B were 93.0% at final follow-up. Side-to-side difference was improved from 6.7 mm to 2.1 mm at final follow-up. Complications occurred in 3 patients, a reruptured due to trauma at 2 years after surgery and a deep infection and a superficial infection. Conclusions: The mid-term follow-up results of ACL reconstruction with the PINN-ACL CrossPin system were satisfactory. The PINN-ACL CrossPin can be considered as a useful instrument for short graft fixation.
Original language | English |
---|---|
Pages (from-to) | 43-48 |
Number of pages | 6 |
Journal | Knee Surgery and Related Research |
Volume | 27 |
Issue number | 1 |
DOIs | |
State | Published - Mar 2015 |
Keywords
- Anterior cruciate ligament
- PINN-ACL CrossPin
- Reconstruction
- Semitendinosus tendon