TY - JOUR
T1 - Structural response of steel-fiber-reinforced concrete beams under various loading rates
AU - Lee, Jin Young
AU - Shin, Hyun Oh
AU - Yoo, Doo Yeol
AU - Yoon, Young Soo
N1 - Publisher Copyright:
© 2017 Elsevier Ltd
PY - 2018/2/1
Y1 - 2018/2/1
N2 - This study presents the rate-dependent structural behavior of reinforced concrete (RC) beams with and without steel fibers and stirrups. Three different loading rates, i.e., quasi-static, impact, and blast loading, were adopted, and three different volume fractions (vf) of hooked steel fibers, i.e., 0, 0.5, and 1%, were considered. The test results indicate that the addition of steel fibers enhanced the static, impact, and blast resistances of the RC beams in terms of higher load carrying capacity, higher energy absorption capacity, and lower maximum and residual displacements. However, the inclusion of 0.5 and 1 vol% steel fibers was insufficient to prevent brittle shear failure of the RC beams without stirrups. On the other hand, brittle shear failure was effectively prevented by incorporating stirrups. The beams including both 0.5 vol% steel fibers and stirrups demonstrated the highest performance, regardless of the strain rate in all the three loading conditions. Lastly, the static shear strengths of reinforced steel-fiber-reinforced concrete beams were effectively predicted based on Aoude's model, and the effectiveness of using steel fibers was greatest under the static loading condition, as compared with impact and blast loading conditions.
AB - This study presents the rate-dependent structural behavior of reinforced concrete (RC) beams with and without steel fibers and stirrups. Three different loading rates, i.e., quasi-static, impact, and blast loading, were adopted, and three different volume fractions (vf) of hooked steel fibers, i.e., 0, 0.5, and 1%, were considered. The test results indicate that the addition of steel fibers enhanced the static, impact, and blast resistances of the RC beams in terms of higher load carrying capacity, higher energy absorption capacity, and lower maximum and residual displacements. However, the inclusion of 0.5 and 1 vol% steel fibers was insufficient to prevent brittle shear failure of the RC beams without stirrups. On the other hand, brittle shear failure was effectively prevented by incorporating stirrups. The beams including both 0.5 vol% steel fibers and stirrups demonstrated the highest performance, regardless of the strain rate in all the three loading conditions. Lastly, the static shear strengths of reinforced steel-fiber-reinforced concrete beams were effectively predicted based on Aoude's model, and the effectiveness of using steel fibers was greatest under the static loading condition, as compared with impact and blast loading conditions.
KW - Dynamic response factor
KW - Reinforced concrete beam
KW - Steel fiber
KW - Stirrup
KW - Strain rate
UR - http://www.scopus.com/inward/record.url?scp=85035119138&partnerID=8YFLogxK
U2 - 10.1016/j.engstruct.2017.11.052
DO - 10.1016/j.engstruct.2017.11.052
M3 - Article
AN - SCOPUS:85035119138
SN - 0141-0296
VL - 156
SP - 271
EP - 283
JO - Engineering Structures
JF - Engineering Structures
ER -