Abstract
Generally, high-power inverters are composed of power semiconductors connected in parallel such as an IGBT. The simplest way to control semiconductors connected in parallel is to control all switches with the same switching sequence. However, this control method can cause high switching losses in all switches and imbalance in life among switches. This paper proposes switching patterns that minimize switching losses by individual control of the switches. Different switching losses are calculated depending on the switching pattern and compared by experiment. Through this process, switching patterns that minimize losses are analyzed. Experimental results show that the overall inverter efficiency can be increased with the proposed method under the various current conditions.
| Original language | English |
|---|---|
| Pages (from-to) | 750-756 |
| Number of pages | 7 |
| Journal | Transactions of the Korean Institute of Electrical Engineers |
| Volume | 70 |
| Issue number | 5 |
| DOIs | |
| State | Published - May 2021 |
Keywords
- Efficiency
- Inverter
- Parallel connection
- Power semiconductor
- Switching losses
- Switching pattern
Fingerprint
Dive into the research topics of 'Study of the method to minimize switching loss by individual control of parallel switches'. Together they form a unique fingerprint.Cite this