Study on the address discharge characteristics for the improvement of the mis-firing problem in AC PDP

Won Jae Jeon, Dong Hun Kim, Seok Hyun Lee

Research output: Contribution to journalArticlepeer-review

Abstract

Unstable sustain discharges can occur at the bottom cells of the panel at high temperature. To solve this problem, the wall charge variation during an address period was investigated. A test panel of 7.5 inch XGA level was used and one green cell was measured. In order to realize operating condition equal to that of the bottom cells of 50 inch panel, the addressing stress pulses are applied. It seems that the resultant wall charge loss during address period increased with increase of stress time, temperature, pressure and Xe %. Wall charge loss increases with potential difference between scan electrode and address electrode, therefore wall charge loss can be minimized by the increase of scan voltage during address period.

Original languageEnglish
Pages (from-to)1151-1156
Number of pages6
JournalTransactions of the Korean Institute of Electrical Engineers
Volume58
Issue number6
StatePublished - Jun 2009

Keywords

  • Address discharge
  • Misfiring
  • PDP
  • Wall charge

Fingerprint

Dive into the research topics of 'Study on the address discharge characteristics for the improvement of the mis-firing problem in AC PDP'. Together they form a unique fingerprint.

Cite this