TY - JOUR
T1 - The burden and risk factors for infection of transvenous cardiovascular implantable electronic device
T2 - A nationwide cohort study
AU - Yang, Pil Sung
AU - Jeong, Jaehan
AU - You, So Jeong
AU - Yu, Hee Tae
AU - Kim, Tae Hoon
AU - Sung, Jung Hoon
AU - Lee, Sang Soo
AU - Park, Hyung Deuk
AU - Joung, Boyoung
N1 - Publisher Copyright:
Copyright © 2019. The Korean Society of Cardiology.
PY - 2019
Y1 - 2019
N2 - Background and Objectives: There are limited published data on the incidence and cost associated with cardiac implantable electrical device (CIED) infection for Asian patients. We analyzed the infection burden associated with the implantation of CIEDs in Korea. Methods: In the Health Insurance Review & Assessment Service (HIRA) database during the period from January 1, 2014 to December 31, 2016, we identified 16,908 patients with CIED implantation. CIED infection was defined as either: 1) Infection-related diagnosis code by the Korean Standard Classification of Diseases after any CIED procedure; or 2) CIED removal along with systemic infection. Results: The proportions of first implantation and replacement were 77.6% and 22.4%, respectively. During the follow-up period of 17.1±10.6 months, a total of 462 patients had CIED infection with incidence of 1.95 per 100 person-years with higher infection rate in replacement than first implantation (3.97 vs. 1.4 per 100 person-years, p<0.001). The average cost per person was US$ 16,584 (pacemaker, $13,736; implantable cardioverter defibrillator, $28,402; cardiac resynchronization therapy, $29,674). The risk factors of CIED infection were generator replacement (adjusted hazard ratio [aHR], 3.14; 95% confidence interval [CI], 2.60–3.78), diabetes mellitus (aHR, 1.94; 95% CI, 1.58–2.38), and congestive heart failure (aHR, 1.86; 95% CI, 1.51–2.28). Conclusions: The rate of CIED infection in Korea was 1.95 per 100 person-years with average cost of US$ 16,584. The most important risk factor was generator replacement. This result suggests that generator replacement should be performed cautiously to avoid CIED infection.
AB - Background and Objectives: There are limited published data on the incidence and cost associated with cardiac implantable electrical device (CIED) infection for Asian patients. We analyzed the infection burden associated with the implantation of CIEDs in Korea. Methods: In the Health Insurance Review & Assessment Service (HIRA) database during the period from January 1, 2014 to December 31, 2016, we identified 16,908 patients with CIED implantation. CIED infection was defined as either: 1) Infection-related diagnosis code by the Korean Standard Classification of Diseases after any CIED procedure; or 2) CIED removal along with systemic infection. Results: The proportions of first implantation and replacement were 77.6% and 22.4%, respectively. During the follow-up period of 17.1±10.6 months, a total of 462 patients had CIED infection with incidence of 1.95 per 100 person-years with higher infection rate in replacement than first implantation (3.97 vs. 1.4 per 100 person-years, p<0.001). The average cost per person was US$ 16,584 (pacemaker, $13,736; implantable cardioverter defibrillator, $28,402; cardiac resynchronization therapy, $29,674). The risk factors of CIED infection were generator replacement (adjusted hazard ratio [aHR], 3.14; 95% confidence interval [CI], 2.60–3.78), diabetes mellitus (aHR, 1.94; 95% CI, 1.58–2.38), and congestive heart failure (aHR, 1.86; 95% CI, 1.51–2.28). Conclusions: The rate of CIED infection in Korea was 1.95 per 100 person-years with average cost of US$ 16,584. The most important risk factor was generator replacement. This result suggests that generator replacement should be performed cautiously to avoid CIED infection.
KW - Cost
KW - Implantable cardioverter-defibrillator
KW - Infection
KW - Pacemaker
KW - Risk factors
UR - http://www.scopus.com/inward/record.url?scp=85072283330&partnerID=8YFLogxK
U2 - 10.4070/kcj.2018.0361
DO - 10.4070/kcj.2018.0361
M3 - Article
AN - SCOPUS:85072283330
SN - 1738-5520
VL - 49
SP - 742
EP - 752
JO - Korean Circulation Journal
JF - Korean Circulation Journal
IS - 8
ER -