The korean repeatable battery for the assessment of neuropsychological status-update: Psychiatric and neurosurgery patient sample validity

Jong Ok Park, Bon Hoon Koo, Ji Yean Kim, Dai Seg Bai, Mun Seon Chang, Oh Lyong Kim

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

Objective: This study aimed to validate the Korean version of the Repeatable Battery for the Assessment of Neuropsychological Status Update (K-RBANS). Methods: We performed a retrospective analysis of 283 psychiatric and neurosurgery patients. To investigate the convergent validity of the K-RBANS, correlation analyses were performed for other intelligence and neuropsychological test results. Confirmatory factor analysis was used to test a series of alternative plausible models of the K-RBANS. To analyze the various capabilities of the K-RBANS, we compared the area under the receiver operating characteristic (ROC) curves (AUC). Results: Significant correlations were observed, confirming the convergent validity of the K-RBANS among the Total Scale Index (TSI) and indices of the K-RBANS and indices of intelligence (r=0.47–0.81; p<0.001) and other neuropsychological tests at moderate and above significance (r=0.41–0.63; p<0.001). Additionally, the results testing the construct validity of the K-RBANS showed that the second-order factor structure model (model 2, similar to an original factor structure of RBANS), which includes a first-order factor comprising five index scores (immediate memory, visuospatial capacity, language, attention, delayed memory) and one higher-order factor (TSI), was statistically acceptable. The comparative fit index (CFI) (CFI, 0.949) values and the goodness of fit index (GFI) (GFI, 0.942) values higher than 0.90 indicated an excellent fit. The root mean squared error of approximation (RMSEA) (RMSEA, 0.082) was considered an acceptable fit. Additionally, the factor structure of model 2 was found to be better and more valid than the other model in χ2 values (Δχ2 =7.69, p<0.05). In the ROC analysis, the AUCs of the TSI and five indices were 0.716–0.837, and the AUC of TSI (AUC, 0.837; 95% confidence interval, 0.760–0.896) was higher than the AUCs of the other indices. The sensitivity and specificity of TSI were 77.66% and 78.12%, respectively. Conclusion: The overall results of this study suggest that the K-RBANS may be used as a valid tool for the brief screening of neuropsychological patients in Korea.

Original languageEnglish
Pages (from-to)125-135
Number of pages11
JournalJournal of Korean Neurosurgical Society
Volume64
Issue number1
DOIs
StatePublished - Jan 2021

Keywords

  • Construct validity
  • Convergent validity
  • K-RBANS

Fingerprint

Dive into the research topics of 'The korean repeatable battery for the assessment of neuropsychological status-update: Psychiatric and neurosurgery patient sample validity'. Together they form a unique fingerprint.

Cite this