The novel calibration method for 3-DOF measurement system

Kwang Il Lee, Jin Seok Jang, Hyun Woo Lee, Suk Jin Kim, Sang Ryong Lee, Seung Han Yang

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

In this paper, a novel calibration method is developed to improve the measurement accuracy of 3-DOF measurement system. The squareness error between three sensors and misalignment error with respect to reference coordinate of machine tool are calibration parameters. To estimate these parameters, reference ball is used and moved in the measuring ranges of 3-DOF measurement system. The relation between calibration parameters, position of reference ball, measured data of sensors are defined using geometric constraint and estimated using least square method. Finally, simulation is done to check the feasibility of developed calibration method. The result of simulation revealed the validation of developed method.

Original languageEnglish
Title of host publicationProduct Design and Manufacture
Pages440-443
Number of pages4
DOIs
StatePublished - 2012
Event2011 International Conference on Applied Mechanics, Materials and Manufacturing, ICAMMM 2011 - Shenzhen, China
Duration: 18 Nov 201120 Nov 2011

Publication series

NameApplied Mechanics and Materials
Volume120
ISSN (Print)1660-9336
ISSN (Electronic)1662-7482

Conference

Conference2011 International Conference on Applied Mechanics, Materials and Manufacturing, ICAMMM 2011
Country/TerritoryChina
CityShenzhen
Period18/11/1120/11/11

Keywords

  • 3-DOF measurement system
  • Calibration method
  • Least square method
  • Misalignment error
  • Squareness error