Use of 2.0 mini plate system as reduction plate

Jong Keon Oh, Dipit Sahu, Jong Woong Park, Chang Wug Oh, Jin Ho Hwang

Research output: Contribution to journalArticlepeer-review

6 Scopus citations

Abstract

Fracture stabilization and reduction using temporary plates during intramedullary tibial nailing was introduced as a novel concept in fracture surgery by Benirschke et al. (Orthop Trans 18:1055-1056, 1995). The concept of temporary reduction using one-third tubular plates proved useful in aiding metaphyseal and periarticular fracture fixation also. However, planning the strategic location of final plate was the main limitation with this technique using one-third tubular plates. We used 2.0 mini plates as provisional reduction plates that solved the issue of planning and placement of plates. The main advantage of our technique is that the final definitive plate can be applied directly over the mini plates. Here, we will describe our technique using relevant fracture case in metaphyseal-periarticular location.

Original languageEnglish
Pages (from-to)1239-1242
Number of pages4
JournalArchives of Orthopaedic and Trauma Surgery
Volume130
Issue number10
DOIs
StatePublished - Oct 2010

Keywords

  • 2.0 Mini plate
  • Periarticular fracture
  • Reduction plate
  • Temporary reduction

Fingerprint

Dive into the research topics of 'Use of 2.0 mini plate system as reduction plate'. Together they form a unique fingerprint.

Cite this