TY - JOUR
T1 - Usefulness of cordless ultrasonic cutting energy devices in endoscopic nipple-sparing mastectomy
T2 - a retrospective study
AU - Kang, Byeongju
AU - Keum, Heejung
AU - Park, Ho Yong
AU - Jung, Jin Hyang
AU - Kim, Wan Wook
AU - Lee, Jeeyeon
N1 - Publisher Copyright:
Copyright © 2024, the Korean Surgical Society.
PY - 2024/3
Y1 - 2024/3
N2 - Purpose: Endoscopic nipple-sparing mastectomy (E-NSM) is a minimally invasive surgical technique that shows good results in patients with breast cancer. The authors compared 3 different types of commercial energy devices to examine their efficacy and safety in E-NSM performed with breast reconstruction. Methods: A total of 36 cases of E-NSM were conducted with either Sonicision (S group, n = 11), Harmonic (H group, n = 6), or Thunderbeat (T group, n = 19). The clinicopathologic factors and postoperative complications, including nipple or skin necrosis and surgical site seroma volume, were evaluated for 3 months after surgery. Results: The surgical duration of E-NSM was significantly shorter in the S group than in the H group (P = 0.043) and T group (P = 0.037). However, the total surgical duration including E-NSM and breast reconstruction, and the total and daily drainage volume of postoperative seroma did not differ significantly among the 3 groups. Even when the energy devices were compared according to their working principle, i.e., ultrasonic (S and H) vs. hybrid (T), the total breast surgery duration and total and daily drainage volume of seroma showed no difference between the 2 groups. Although surgeon satisfaction did not significantly differ when using 3 devices for E-NSM (P = 0.428), surgeon’s fatigue was found to be lowest in the S group, though it was not significant (P = 0.064). Conclusion: Any energy device can be safely used for E-NSM with breast reconstruction without causing any major complications. However, cordless ultrasonic energy devices allow greater mobility for the surgeon and, therefore, may shorten surgical time in breast surgery.
AB - Purpose: Endoscopic nipple-sparing mastectomy (E-NSM) is a minimally invasive surgical technique that shows good results in patients with breast cancer. The authors compared 3 different types of commercial energy devices to examine their efficacy and safety in E-NSM performed with breast reconstruction. Methods: A total of 36 cases of E-NSM were conducted with either Sonicision (S group, n = 11), Harmonic (H group, n = 6), or Thunderbeat (T group, n = 19). The clinicopathologic factors and postoperative complications, including nipple or skin necrosis and surgical site seroma volume, were evaluated for 3 months after surgery. Results: The surgical duration of E-NSM was significantly shorter in the S group than in the H group (P = 0.043) and T group (P = 0.037). However, the total surgical duration including E-NSM and breast reconstruction, and the total and daily drainage volume of postoperative seroma did not differ significantly among the 3 groups. Even when the energy devices were compared according to their working principle, i.e., ultrasonic (S and H) vs. hybrid (T), the total breast surgery duration and total and daily drainage volume of seroma showed no difference between the 2 groups. Although surgeon satisfaction did not significantly differ when using 3 devices for E-NSM (P = 0.428), surgeon’s fatigue was found to be lowest in the S group, though it was not significant (P = 0.064). Conclusion: Any energy device can be safely used for E-NSM with breast reconstruction without causing any major complications. However, cordless ultrasonic energy devices allow greater mobility for the surgeon and, therefore, may shorten surgical time in breast surgery.
KW - Subcutaneous mastectomy
KW - Surgical equipment
KW - Wireless technology
UR - https://www.scopus.com/pages/publications/85186857036
U2 - 10.4174/astr.2024.106.3.147
DO - 10.4174/astr.2024.106.3.147
M3 - Article
AN - SCOPUS:85186857036
SN - 2288-6575
VL - 106
SP - 147
EP - 154
JO - Annals of Surgical Treatment and Research
JF - Annals of Surgical Treatment and Research
IS - 3
ER -